| High Performance Magnetic Flux Vector Generic Inverter. |
|
| |
Characteristic |
|
| |
|
|
|
| |
 |
Output Frequency 0.5~400.0Hz |
|
| |
 |
PWN frequency 2~12KHz |
|
| |
 |
9-step speed setting |
|
| |
 |
Parameter input by key number 0~9 |
|
| |
 |
15 pattern and any V/F pattern |
|
| |
 |
Speed command PID loop for system application |
|
| |
 |
Provide high DPI A/D 14Bits, A/D 12Bits |
|
| |
 |
Built-in ENCODER feedback interface |
|
| |
 |
External analog setting ±10V, 0~10V and 4~20mA |
|
| |
 |
Built-in standard RS422/485 communication port, MODBUS RTU protocol |
|
| |
 |
V/F open/close loop control, Vector control, Vector close loop control, Torque control |
|
| |
 |
Motor Parameter autotuning, automatic voltage compensation and slip compensation |
|
| |
 |
Control Performance upgraded by adding encoder card, PWN input, analog 12bit ± 10 V input/output, CAN BUS communication interface |
|
|
|
 |
| |
|
|
| |
|
|
| |
Standard Specification |
|
| |
A. 200V 3 phase
|
Motor
(KW)
|
5.5
|
7.5
|
11
|
15
|
22
|
30
|
37
|
45
|
|
Type
(CT-2002V-)
|
5A5
|
7A5
|
011
|
015
|
022
|
030
|
037
|
045
|
|
Rated
current (A)
|
23
|
33
|
48
|
61
|
86
|
125
|
150
|
170
|
|
Rated
capacity (KVA)
|
9.2
|
13.1
|
19.1
|
24.3
|
34.3
|
49
|
60
|
68
|
|
Input
power supply
|
3f 220V ±10%, 50/60Hz ±5%
|
|
Output
voltage
|
3f 200V, 220V, 230V
|
|
Control
method
|
Space Vector P.W.M
|
|
Starting
torque
|
150% / 3Hz ( 150% / 0 r.p.m Vector control with
PG )
|
|
Speed
control range
|
1:100 ( 1:1000, Vector control with PG )
|
|
Speed
control precision
|
±1% ( ±0.05%, Vector control with
PG )
|
|
Speed
response
|
5Hz ( 20Hz, Vector control with PG )
|
|
Torque
limit
|
250%, 4 quarters setting
|
|
Frequency
precision
|
Digital setting: ±0.01%, Analog
input: ±0.1% (35?)
|
|
Frequency
resolution
|
Digital setting: 0.01 Hz, Analog input:
0.01 Hz/60 Hz (13 bit + sign)
|
|
Frequency
range
|
0.00 ~ 400.00 Hz
|
|
V/f ratio
|
15 patterns, or arbitrary curve
|
|
Voltage
(torque) compensation
|
0~15.0% voltage compensation, or automatic voltage
compensation
|
|
Accel./decel.
time
|
0.00~6000.0 sec
|
|
Motor
braking
|
100% with DBR
|
20%
|
|
Standard
feature
|
Autotuning,Jog operation,Speed reference limit,Skip
frequency setting,Multi-step speed reference setting,DC
injection braking,PID controller,Analog output
(12bit),Serial communication.
|
|
Display
|
7-segmnet LED displays:Frequency,Voltage,Current,Torque,Function
list,Setting value,Fault status.
|
|
Protective
function
|
Low power,Over voltage,Stall prevention,Overload,Over
current,Overheat,Over speed,Encoder error.
|
|
Overload
capacity
|
150% 60sec,adjustable
|
|
Altitude
|
Indoor, below 1000meter altitude
|
|
Ambient
temperature
|
-10? ~ 40? (50? with covers removed)
|
|
Vibration
|
Below 0.5G
|
|
Humidity
|
Relative humidity between 45% and 90% (non-condensing)
|
|
Protective
feature
|
Fan ventilation
|
|
Closed
|
Half closed
|
|
Weight
(kg)
|
8
|
13
|
13
|
22
|
23
|
46
|
49
|
50
|
B. 400V 3 phase
|
Motor
(KW)
|
5.5
|
7.5
|
11
|
15
|
22
|
30
|
37
|
45
|
55
|
75
|
|
Type
(CT-2004V-)
|
5A5
|
7A5
|
011
|
015
|
022
|
030
|
037
|
045
|
055
|
075
|
|
Rated
current (A)
|
13
|
17.3
|
24
|
31
|
52
|
65
|
71
|
93
|
110
|
156
|
|
Rated
capacity (KVA)
|
10.4
|
13.8
|
19.1
|
24.7
|
41.4
|
51.8
|
56.6
|
74
|
87.6
|
124
|
|
Input
power supply
|
3f 380V ~ 440V ±10%, 50/60Hz ±5%
|
|
Output
voltage
|
3f 380V, 415V, 440V
|
|
Control
method
|
Space Vector P.W.M
|
|
Starting
torque
|
150% / 3Hz ( 150% / 0 r.p.m Vector control with
PG )
|
|
Speed
control range
|
1:100 ( 1:1000, Vector control with PG )
|
|
Speed
control precision
|
±1% ( ±0.05%, Vector control with
PG )
|
|
Speed
response
|
5Hz ( 20Hz, Vector control with PG )
|
|
Torque
limit
|
250%, 4 quarters setting
|
|
Frequency
precision
|
Digital setting: ±0.01%, Analog
input: ±0.1% (35?)
|
|
Frequency
resolution
|
Digital setting: 0.01 Hz, Analog input:
0.01 Hz/60 Hz (13 bit + sign)
|
|
Frequency
range
|
0.00 ~ 400.00 Hz
|
|
V/f ratio
|
15 patterns, or arbitrary curve
|
|
Voltage
(torque) compensation
|
0~15.0% voltage compensation, or automatic voltage
compensation
|
|
Accel./decel.
time
|
0.00~6000.0 sec
|
|
Motor
braking
|
100% with DBR
|
20%
|
|
Standard
feature
|
Autotuning, Jog operaton, Speed reference limit,
Skip frequency setting, Multi-step speed reference
setting, DC injection braking, PID controller,
Analog output (12bit), Serial communication.
|
|
Display
|
7-segmnet LED displays:Frequency,Voltage,Current,Torque,Function
list,Setting value,Fault status.
|
|
Protective
function
|
Low power,Over voltage,Stall prevention,Overload,Over
current,Overheat,Over speed,Encoder error.
|
|
Overload
capacity
|
150% 60sec,adjustable
|
|
Altitude
|
Indoor, below 1000meter altitude
|
|
Ambient
temperature
|
-10? ~ 40? (50? with covers removed)
|
|
Vibration
|
Below 0.5G
|
|
Humidity
|
Relative humidity between 45% and 90% (non-condensing)
|
|
Protective
feature
|
Fan ventilation
|
|
Closed
|
Half closed
|
|
Weight
(kg)
|
8
|
15
|
15
|
16
|
25
|
26
|
49
|
51
|
53
|
79
|
|
|
|
|